Production-line drive fault diagnosis

A food-processing machine would not restart after a spare motor and gearbox were installed. Electron checked the removed motor, reviewed the Yaskawa GA500 drive’s fault history, and identified an internal Safe Torque Off fault. The drive had also recorded repeated overloads, the latest at 41.6 A. Electron backed up the drive parameters and network settings for a replacement.
Documented outcome
Electron documented an internal Safe Torque Off fault and saved the Yaskawa GA500 parameters and network settings for a replacement.
Restart fault and overload history kept distinct
The internal Safe Torque Off fault relates to the restart issue. The repeated overload history—including the latest recorded 41.6 A overload—is separate drive history, not presented as the cause of the restart fault.
Project Photo Details


Customer-neutral project summary. Client names, internal identifiers, pricing, and facility addresses are intentionally omitted.